ES150

Inspection & Maintenance

Maintenance schedule and inspection requirements for the Jefa Steering ES150 electric outboard steering system.

Continuous failure to follow the inspection and maintenance requirements may result in degradation of system performance and potential system failure.

Regular Inspection

All components should be regularly inspected, approximately every 100 hours of use, for rust or non-superficial damage. The following areas should be checked:

  • Seals on actuator shaft
  • All exposed rubber grommets and O-rings
  • Cable connection to actuator housing
  • Cable connections on EMC-box
  • Cable connection to steering wheel hub (if exposed)
  • Surface of actuator shaft

Any significant rusting, degradation or non-superficial damage could impact the system's ability to keep out water and potentially result in system failure.

Maintenance Schedule

Regular

Clean the actuator axle regularly. Minimising dirt and salt accumulation on the axle will maintain the integrity of the seals, ensure smooth operation and extend service life.

Replace any component with significant rusting, degradation or non-superficial damage.

Annual

Apply a light oil to the actuator shaft once per year.

Important: Do not use grease on the actuator shaft. Grease can gather within the shaft seals, compromising waterproofing. Use light oil only.

Component Replacement

Replace any component with significant rusting, degradation or non-superficial damage. For replacement parts, please contact Jefa Steering A/S.

Need replacement parts or support?

Contact Jefa Steering A/S for replacement components or technical assistance.

Contact Us →